Toilet rooms can be configured in many different ways but the same requirements apply including those for fixtures doors and turning space.
Ada restroom stall door requirements.
This example shows a door swing located outside fixture clearances obviating the need for wheelchair space beyond the arc of the door swing and turning space free of any overlapping elements left.
The minimum width of the stall is 60 inches 1525 mm.
4 13 12 automatic doors and power assisted doors.
If an automatic door is used then it shall comply with ansi bhma a156 10 1985.
The centerline of the water closet is 18 inches 455 mm from the side wall.
Need help ordering ada compliant restroom materials.
The location of the door is in front of the clear space and diagonal to the water closet with a maximum stile width of 4 inches 100 mm.
This guide explains requirements in the ada standards for clear floor or ground space and turning space.
They should be usable with one hand without the need to tightly grasp pinch or twist the wrist.
Specific questions call the toll free ada information line at 800 514 0301 voice or 800 514 0383.
Figure 30 a standard stall.
Slowly opening low powered automatic doors shall comply with ansi a156 19 1984.
Examples of ada toilet stalls.
If toilet stall approach is from the latch side of the stall door clearance between the door side of the stall and any obstruction may be reduced to a minimum of 42 in 1065 mm.
When ordering ada bathroom toilet stalls please send us your plans so we can quote you.
Users shouldn t have to exert more than 5 pounds of force to use the faucet to meet ada requirements.
Figure 30 a standard stall.
A 36 stall door is used most often with a wheel fitting through that opening.
Toilet stall doors including door hardware shall comply with 4 13.
Or for answers to.
Clearances are required at accessible elements fixtures and controls so that people with disabilities including those who use wheelchairs can approach and use them.
The ada compliant restroom.
To see all of the ada compliance requirements see the 2010 ada standards for accessible design at www ada gov.
Alterations to the meet the readily achievable requirements of title iii of the americans with disabilities act may be limited the actual work of the project.
5 common ada restroom compliance mistakes.
Ada standards for accessible design can be downloaded from www ada.
Ada compliance can be overwhelming and we want to help.
Certain ada compliance issues seem to crop up more frequently than others but it s important to note that the following is not an exhaustive list.
Ada compliant urinals should be stall type or wall hung at a maximum of 17 inches from the floor.