Ada Hi Low Drinking Fountain Requirements

Chapter 6 Drinking Fountains United States Access Board

Chapter 6 Drinking Fountains United States Access Board

Drinking Fountains And Knee Clearance Abadi Access Abadi Access

Drinking Fountains And Knee Clearance Abadi Access Abadi Access

Ada Compliance Drinking Fountains Water Coolers Ada Compliance

Ada Compliance Drinking Fountains Water Coolers Ada Compliance

Haws Wall Mounted Drinking Fountains

Haws Wall Mounted Drinking Fountains

Elkay Ezostl8sc Touchless Automatic Chilled Drinking Fountain Wall Mount Ada Bi Level Stainless Steel

Elkay Ezostl8sc Touchless Automatic Chilled Drinking Fountain Wall Mount Ada Bi Level Stainless Steel

Wheelchair Accessible Wall Mount Drinking Fountains

Wheelchair Accessible Wall Mount Drinking Fountains

Wheelchair Accessible Wall Mount Drinking Fountains

However if you are required to provide more than two drinking fountain then 50 must be at lower height while the other 50 at standing height.

Ada hi low drinking fountain requirements.

Drinking fountains for children s use 602 1 602 6 drinking fountains designed specifically for children ages 12 and younger can provide a parallel approach instead of a forward approach if the spout is 30 inches high max and no more than 3 1 4 inches from the front edge of the unit including bumpers 602 2 ex. Manufacturers of drinking fountains all have accessible units available that will meet the requirements listed below. X plan of hi low drinking fountain 11b 602 6 water flow. 19 in depth with clear knee space between bottom of apron and floor not less than 27 high 30 wide and 8 deep from front edge of fountain.

Yet the accessibility standard only specified a requirement for the low drinking fountain. The spout shall provide a flow of water at least 4 in 100 mm high so as to allow the insertion of a cup or glass under the flow of water. The accessibility standards have requirements for both types. Federal accessibility code requires that where drinking fountains are provided on an exterior site or on an interior floor no fewer than two one standard one accessible or one hi lo drinking fountain an accessible standard combination unit shall be provided and those with leading edges more than 27 above the floor must be placed in an alcove space or between wing walls not.

For many years the ada recommended a high and low drinking fountain. They should also have a minimum clear floor space of 30 by 48 for wheelchair accommodation. A low drinking fountain is designed for a person confined to a wheelchair. The spout shall provide a flow of water 4 inches high minimum and.

First the difference between the two. That all changed when the 2006 international building code was published. Drinking fountains drinking fountain spout location figure 11b 602 5 hi fountain low fountain cl 36 min figure 11b 305 7 1 maneuvering clearance in an alcove forward approach note. The americans with disabilities act ada requires wall mounted drinking fountain units to have a clear knee space of at least 27 high 30 wide and 17 to 19 deep.

Water Bottle Filling Drinking Fountains

Water Bottle Filling Drinking Fountains

Haws H1119 8 Refrigerated Hi Lo Ada Drinking Fountain Belson Outdoors

Haws H1119 8 Refrigerated Hi Lo Ada Drinking Fountain Belson Outdoors

Haws Hi Lo Ada Drinking Fountain With Grille Back Panel Belson Outdoors

Haws Hi Lo Ada Drinking Fountain With Grille Back Panel Belson Outdoors

107 14 Hhl Filtrine

107 14 Hhl Filtrine

Source : pinterest.com