60 inches 1525 mm 18 inches 455 mm from front.
Ada door clearance pull side.
Latch approach pull side of door.
48 perpendicular to the doorway without closer 54 with closer but still have 24 parallel to doorway beyond latch.
Maneuvering clearances shall extend the full width of the doorway and the required latch side or hinge side clearance.
Minimum maneuvering clearances at doors and gates shall comply with 404 2 4.
If the latch side clearance is at least 42.
You can use the face of the wall as part of the maneuvering clearance.
All doors in alcoves shall comply with the clearances for front approaches.
This is based on a new door installation or a door that is on an accessible route.
In a nutshell what this is saying is that the 18 minimum clearance required at the pull side of the door or the 12 on the push side of a door with a closer and a latch is not required if the door is recessed no more than 8.
The maneuvering clearance at the door with a 36 door is then 48 x 60.
Entry doors to hospital patient rooms shall not be required to provide the clearance beyond the latch side of the door.
On the pull side of hinge approaches 36 min.
Front approaches to pull side of swinging doors shall have maneuvering space that extends from the hinge side of the door to 18 inches 455 mm minimum 24 inches 610 mm preferred beyond the latch side of the door and 60 inches 1525 mm minimum perpendicular to the doorway.
Space at least 60 deep in front of a door will accommodate a forward approach except in case of hinge approaches on the pull side.
Parallel to doorway beyond latch side unless noted from front.
Door or gate side.
Entry doors to hospital patient rooms shall not be required to provide the clearance beyond the latch side of the door.
60 inches 1525 mm 36 inches 915 mm from hinge side.
Maneuvering clearances at doors.
Latch side clearance is required if the depth is 60 min.
On the parallel side beyond the latch is 24 inches should the door need to swing open.
Pull side 44 push side min per cbc 60 24 per cbc 24 48 min 54 min min pull side push side.
48 inches 1220 mm 0 inches 0 mm 1.
404 2 4 1 swinging doors and gates swinging doors and gates shall have maneuvering clearances complying with table 404 2 4 1.
The depth can be 54 min.
Door clearances sources 26 ada sources 309 operable parts 404 2 manual doors doorways and manual gates 404 2 2 double leaf doors and gates.