804 3 1 clear floor or ground space.
Ada clear floor area latch approach.
Sufficient clear floor or ground space is required at accessible controls operable parts drinking fountains lavatories and sinks atms and fare machines appliances beds and other elements.
410 4 platform to runway clearance.
All required door clear floor spaces to have a maximum slope of 1 48 2 per cbc.
On the pull side of hinge approaches 36 min.
Ada sources 309 operable parts 404 2 manual doors doorways and manual gates 404 2 2 double leaf doors and gates.
If the latch side clearance is at least 42.
Entry doors to acute care hospital bedrooms for in patients shall be exempted from the requirement for space at the latch side of the door see dimension x in figure below if the door is at least 44 in 1120 mm wide.
The clear floor or ground space shall be centered on the appliance.
A clear floor or ground space complying with 305 positioned for parallel approach shall be provided.
410 6 doors and gates.
There are many regulations and calculations that go into designing an ada ramp but the ramp landing size is commonly miscalculated because the door size door swing and ramp approach are often not considered.
The clearance between the platform sill and the edge of any runway landing shall be 1 1 4 inch 32 mm maximum.
Latch approach sliding folding doors gates with latch approach use.
611 2 clear floor space.
A slide side approach to a sliding or folding door requires a clear space in front of the door measuring a min.
Operable parts including doors lint screens and detergent and bleach compartments shall comply with 309.
Clear floor space in platform lifts shall comply with 305.
The depth can be 54 min.
Arrangements shown for standard toilet stalls may be reversed to allow either a left or right hand approach.
Latch side clearance is required if the depth is 60 min.
The clear floor or ground space shall be centered on the kitchen work surface and shall provide knee and toe clearance complying with 306.
A clear floor space complying with 305 positioned for a forward approach shall be provided.
Clear floor or ground space.
Any ramp system that is intended for public use must comply with the americans with disabilities act ada.
410 3 clear floor space.
Space at least 60 deep in front of a door will accommodate a forward approach except in case of hinge approaches on the pull side.
4 13 7 two doors in series.
Provisions for these elements apply the clear floor or ground specifications in 305.
Controls for platform lifts shall comply with 309.
Requirement beside the door on the latch side and so the clear space box may slide left or right as necessary in front of the door in this scenario.
If the depth of a standard toilet stall is increased at least 3 in 75 mm then a floor mounted water closet may be used.