Feminine napkin disposal 7.
Ada bathroom accessories requirements.
Compliance date for title ii.
Provisions for these elements apply the clear floor or ground specifications in 305.
A 48 inch high limitation is required for all accessories except those mounted over obstructions including lavatory fixtures which are up to 20 inches deep.
Grab bars must be installed between 34 and 38 inches above the floor and there must be a separation between the grab bar and the wall surface of at least 1 1 2 inches.
Hand dryer of paper towel dispenser 3.
For more information for information about the ada including the revised 2010 ada regulations please visit the department s website www ada gov.
When the reach depth is over 20 inches deep a reach range of 44 inches applies.
State and local government facilities must follow the requirements of the 2010 standards including both the title ii regulations at.
Toilet seat cover dispenser 6.
Grade ii dots 1 10 on center in each cell with 2 10 space between cells raised 1 40 obstacles.
Items such as soap dispensers paper towel dispensers and waste receptacles must meet minimum accessibility requirements.
In the few places where requirements between the two differ the requirements of 28 cfr 35 151 prevail.
Figure 11b 604 8 1 4 wheelchair accessible toilet compartment toe clearanc e.
Clear floor space at elements.
Ada standards for accessible design can be downloaded from www ada.
Raised letters braille 5 8 to 2 high rased 1 32 sans serif upper case non glare contrast.
Compliant ada dispenser heights and locations.
Faucets and soap dispensers must meet ada reach range and mounting height requirements.
The operable portions of any accessory should be mounted no lower than 15 inches 380mm above the floor.
Sufficient clear floor or ground space is required at accessible controls operable parts drinking fountains lavatories and sinks atms and fare machines appliances beds and other elements.
And the 2004 adaag at 36 cfr part 1191 appendices b and d.
The bar must be 1 1 4 to 1 1 2 inches in diameter.
A person must be able to approach within 3 of signage without encountering.
An ada compliant grab bar handrail must be fully anchored and have a smooth surface that can be easily grabbed.
Light on dark or dark on light braille.
Where accessories are mounted over obstructions such as counters depending on the nature and depth of the obstruction it is required that they be located between 44 inches and 48 inches 1120 and 1220mm maximum above the finish floor.
Diaper changing stations 5.
Typically accessories may not be located such that the operable portion of the item is above 40 inches from the floor.